又大又黄少妇毛片,日韩av 在线免费观看,99热这里只有精品香蕉,老司机免费午夜福利视频 ,我想要看黄色片,中文有码人妻熟女,久久久久久久 亚洲,久久频这里只有精品99
          歡迎來北京祥生興業科技有限公司!我們將為您提供周到的服務!
          首頁 > 產品中心 > 臨床質譜質控品、校準品 > Chromsystems > MassChrom® Vitamins B1 and B6 in Whole Blood, with Reaction Vials

          產品名稱:MassChrom® Vitamins B1 and B6 in Whole Blood, with Reaction Vials

          產品型號:87000

          產品報價:

          產品特點:

          供應商:祥生興業規格:480TestsMassChrom®VitaminsB1andB6inWholeBlood,withReactionVialsOrderno

          免費咨詢:13681184382

          發郵件給我們:702140183@qq.com

          分享到:

          87000MassChrom® Vitamins B1 and B6 in Whole Blood, with Reaction Vials的詳細資料:

          溫馨提示:僅用于科研,不可用于臨床治療

          • 供應商:

            祥生興業

          • 規格:

            480 Tests

            MassChrom® Vitamins B1 and B6 in Whole Blood, with Reaction Vials


            Order no.: 87000
            480 Tests
            • Vitamin B1 (TPP, thiamine pyrophosphate)
            • Vitamin B6 (PLP, pyridoxal 5’-phosphate)

            Fast and easy sample preparation
            Robust method with high selectivity
            Short run time of 2.5 minutes
            Isotopically-labelled internal standard for each analyte
            With reaction vials

             

            DESCRIPTION

            Clinical relevance

            Vitamin B1 (thiamine) plays an important role in deriving energy from carbohydrates and fats. The active form is thiamine pyrophosphate (TPP), a coenzyme for some enzymatic reactions in carbohydrate metabolism and for pyruvate decarboxylase. TPP is also significantly involved in the oxidative degradation of glucose. The determination of the TPP concentration is more significant than measurements of total thiamine, as by this method only the physiologically active form is taken into account.

            Vitamin B6 comprises pyridoxine, pyridoxamine and pyridoxal, as well as their phosphate derivatives. It is ingested with food and transferred via several enzymatic conversions into its active form, pyridoxal-5’-phosphate (PLP). PLP is involved in nearly one hundred different enzymatic reactions, among other things, as co-factor in amino acid metabolism, and in the formation of haemoglobin or neurotransmitters in the brain.

             

            Product advantages

            • Fast and easy sample preparation
            • Robust method with high selectivity
            • Short run time of 2.5 minutes
            • Isotopically-labelled internal standard for each analyte

             

            This Chromsystems assay enables combined determination of the active forms of vitamin B1 (thiamine pyrophosphate, TPP) and vitamin B6 (pyridoxal 5‘-phosphate, PLP) in whole blood by LC-MS/MS. Sample preparation consists of a simple protein precipitation step, with no need for derivatisation. This makes for a much faster sample preparation and high sample throughput. Analytes and potential interferences are effectively and swiftly separated within 2.5 minutes, indicating the method's high selectivity and speed. The chromatographic separation of the MassChrom® assay is fast enough to ensure a high throughput in the laboratory, but sufficiently resolving for a clear separation of the two analytes with minimal potential matrix effects. Isotope-labelled internal standards for both parameters as well as 6PLUS1® calibrators and MassCheck® controls ensure accurate and precise results. The assay is available in 2 configurations either with reaction vials or with 96 deep well plates.

            CHROMATOGRAM

            Chromatogram 87000 Vitamins B1 and B6

            TECHNICAL DATA

            Method of Analysis

            LC-MS/MS

            Number of Tests

            480

            Parameter

            Vitamin B1 (TPP, thiamine pyrophosphate), Vitamin B6 (PLP, pyridoxal 5’-phosphate)

            Analysis Time

            2.5 min

            Limit of quantification

            3.4 μg/l TPP
            2.8 μg/l PLP

            Linearity

            850 μg/l TPP
            1000 μg/l PLP

            Intraassay

            CV = 1.9–5.2 %

            Interassay

            CV = 2.5–7.1 %

            Specimen

            Whole Blood

            Sample Preparation

            • Pipette 40 μl sample/calibrator/MassCheck® control into reaction vial.
            • Add 80 μl Internal Standard Mix, mix briefly (vortex).
            • Add 350 μl Precipitation Reagent, mix for 1 min (vortex) and centrifuge for 2 min.
            • Transfer supernatant into autosampler vial.
            • Inject 20 μl into the LC-MS/MS system.

            Injection Volume

            20 μl

            Flow rate

            0.5 ml/min

            Column temperature

            30 °C

            Ionisation

            ESI positive

            MS/MS-Mode

            MRM

            Please note

            The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals.

            KIT COMPONENTS

            Components available separately

            Mobile Phase A


            Order no.: 87001

            DETAILS

            Mobile Phase B


            Order no.: 87002

            DETAILS

            Internal Standard Set Vitamins B1 and B6


            Order no.: 87046

            DETAILS

            Precipitation Reagent


            Order no.: 87005

            DETAILS

            Rinsing Solution


            Order no.: 87009

            DETAILS

            Reaction Vials, 2 ml


            Order no.: 33008

            DETAILS

            ACCESSORIES

            PP Screw-on caps, pierceable silicone/PTFE septa, 1.0 mm


            Order no.: J0410

            DETAILS

            Autosampler vials, screw neck, amber glass, 1.5 ml


            Order no.: J0601

            DETAILS

            Analytical column


            Order no.: 87100

            DETAILS

            Tuning Mix Vitamins B1 and B6


            Order no.: 87015

            DETAILS

            Dilution Buffer


            Order no.: 87018

            DETAILS

            Adjustment Reagent


            Order no.: 87019

            DETAILS

            Autosampler vials, screw neck, 15 µl inner cone, clear glass, 1.1 ml


            Order no.: J0602

            DETAILS

            PE Screw-on caps, rubber/PTFE septa, 9 mm


            Order no.: J0504

            DETAILS

            Micro-inserts for autosampler vials


            Order no.: J0403

            DETAILS

            CALIBRATORS

            Calibrators available separately

            6PLUS1® Multilevel Whole Blood Calibrator Set Vitamins B1 and B6


            Order no.: 87039

            DETAILS

            CONTROLS

            Controls available separately

            MassCheck® Vitamins B1 and B6 Whole Blood Controls


             

            DETAILS

           相關同類產品:

          留言框

          • 產品:

          • 您的單位:

          • 您的姓名:

          • 聯系電話:

          • 常用郵箱:

          • 省份:

          • 詳細地址:

          • 補充說明:

          • 驗證碼:

            請輸入計算結果(填寫阿拉伯數字),如:三加四=7

          版權所有  ICP備案號:京ICP備2024091604號-1 管理登陸 技術支持:化工儀器網   總流量:131686  sitemap.xml

          主站蜘蛛池模板: 麻豆国产成人av在线播放欲色| 香蕉亚洲欧洲在线一区| 少妇内射视频播放舔大片| 凹凸国产熟女精品视频| 成人永久免费A∨一级在线播放| 丝袜老师高潮呻吟高潮| 久久天天躁狠狠躁夜夜躁2o2o| 日韩经典精品无码一区| 四虎国产精品成人| 狠狠色狠狠综合久久| 毛片大全真人在线| 久精品视频免费观看| 国语对白做受xxxxx在| 人妻丰满熟妇无码区免费| 91精品久久久久久无码人妻| 成av人片一区二区三区久久| 色综合激情丁香七月色综合| 亚洲国产欧美一区三区成人| 天天爱天天做天天爽夜夜揉| 亚洲精品国产第一区二区尤物| 国产良妇出轨视频在线观看| 国产亚洲999精品AA片在线爽| 色狠狠色狠狠综合天天| 在线中文字幕国产精品| 人妻丝袜乱经典系列| 一本色道久久—综合亚洲| 国产69精品久久久久乱码| 亚洲经典一区二区三区四区| 国产v在线在线观看视频免费| 亚洲色av性色在线观无码| 国产日韩精品欧美一区灰| 人妻少妇精品视频一区二区三区| 无码日韩做暖暖大全免费不卡| 67194熟妇在线观看线路1| 亚洲国产美女精品久久久| 免费的av网站手机版| 中文字幕日韩有码av| 深爱婷婷国产在线精品av| 亚洲国产欧美中文丝袜日韩| 一区二区三区无码免费看| 亚洲国产av高清无码|